Firex 10000 Carbon Monoxide Detector Direct Wire with Battery Back-up (AC/DC)

FIREX 10000
Carbon Monoxide Detector Direct Wire
with Battery Back-up (AC/DC).




Features and Benefits :


  • EXCLUSIVE Monox™ Sensor with True-Test™ Sensor Diagnostics – Verifies that carbon monoxide sensor is working properly, and warns when the sensor is nearing the end of its service life.
  • EXCLUSIVE Monthly Self-Test – Alarm performs a silent internal system test to verify sensor operation.
  • EXCLUSIVE Interconnect Test – In an interconnected system, this feature will alarm the local unit first, then quiet the local unit while the remote units alarm.
  • Front Loading Battery Door (10000C only) – Eliminates battery handling during installation and allows for safe and convenient battery replacement.
  • Battery Pull Tab (10000C only) – Makes installation faster and easier, reducing callbacks due to battery failure. Simply pull tab and press test button.
  • Latching LED Alarm Indicator – After a carbon monoxide alarm condition the single RED light on the triggering alarm blinks until reset.
  • Smart Quiet™ Trigger Alarm Locator – Pushing test button quiets all carbon monoxide alarms EXCEPT the one that triggered the alarm.
  • Smart Quiet™ Low Battery Silencer (10000C only) – Silences low battery alert up to 10 hours.
  • Quick Quiet™ CO Reset – Quiets unwanted carbon monoxide alarms for up to six minutes.
  • Dust Cover – Protects from dust, dirt, fumes or other common contaminants during construction, reducing false alarms and callbacks.
  • Firex Compatible – Interconnects with most Firex smoke and CO alarms. (See Technical Specifications section for interconnectable Firex units.)
  • Ramp-Up Horn – Protects your hearing when testing the alarm by building up the decibel level slowly, giving you time to move away from the horn before the full alarm sequence begins.

Technical Specifications :


Specification Value

Item

10000

Model

COE

Product Weight

8 oz

Operating Temperature

40° – 100°F

Interconnect Qty.

Up to 18 Firex devices maximum. 12 Firex smoke alarms (4518C (model ADC), 4671C (model TPCI) 406C (model G18)). Up to 6 Firex CO alarms (10000C (model COE), 10400C (model COEA). Not compatable with 7000C (model FADCQ), 6045 (model COQ8), 6090 (model COQ6) and 6085 (model COQ3).

Electrical Rating

120V AC, 60HZ, 50mA max

Horn Output

85 decibels at 10 feet

Listings

CAN/CGA-6.19-01

Detection Type

ElectroChemical

Humidity Range

15%-95% relative humidity

0 commentaires:

Enregistrer un commentaire